    首頁 > 案例 > 檢測鑑定

    醫藥公司分機振動檢測

    鋼框架 振动影响 房屋结构安全


    振動檢測振動檢測振動檢測


    工程背景

    項目爲一幢四層鋼框架結構房屋,总建筑面积约7千平方米。现业主发现屋面风机设备运转时,屋面层及四层发生明显振动,为了解振动对房屋结构安全的影响,业主委托我司对该房屋质量及振动情况进行检测,并对结构安全性进行评估,对可能存在的问题提出处理建议。


    解決方案

    採用朗斯測試技術有限公司的LC0132T型加速度传感器记录结构振动时程,并通过同济大学土木工程防灾重点实验室监制SVSA动力测试数据采集仪采集结构各测点加速度时程记录,将测点加速度时程进行积分后,得到各测点的速度时程。将加速度/速度时程峰值与限值进行比较,来判断指标是否超限。

    採用中國建築科學研究院結構研究所PKPM V4.2版本SLABCAD计算软件对房屋屋盖进行了建模,计算出屋盖的自振频率,与现场测试得到的屋盖振动频率对比来判断是否产生共振现象。